Hello selhosted, First time posting here, I hope I’m not too much off topic !
I am currently working on my homeserver. I needed some more storage, but said server being a tiny Thinkcentre I needed to get a PCIe card to connect 4+ drives to it. I went with a PCIe LSI SAS 3008e card instead of a PCIe to SATA3, mainly because it allowed me to get to 12GB/s and also because the external mini-SAS connector seemed more reliable and stronger than standard SATA3 cables.
I plugged everything and technically it did work great. Until I almost burnt myself while touching the card. Thermometer on the picture failed to report how hot it actually was because I could not find the right place to put the sensor, but it really did felt like it was above 100°C/212°F. Even without touching directly the radiator, I could not keep my finger anywhere on the card either.
I knew nothing about SAS cards before, needless to say I’m a bit disappointed :( And my Thinkcentre is also too narrow to let me to put a fan on the card, so now I feel like I just got myself a new paperweight haha.
Are SAS cards always running this hot? Or did I bought a bad model? Also for those like me who are running their homelab with tiny computers, how did you achieve connecting 4+ drives to it ?
Thank you for reading!
EDIT :
Huge thanks for your reactivity and your precious help! I could not take the time to respond to everybody, but your tips are greatly appreciated :)
I finally decided to return the SAS card and its mini-SAS cable. It was not a cost effective solution to get it in the first place, and it still needed more expenses/tinkering by getting a fan for it for an unknown result, and a bigger power consumption than what I expected anyway.
I decided to replace this by a way cheaper NVME to SATA adapter like this one for 20€ :

I also found a 3D printed 10" rack made for my exact model with a NVME cutout.


Sadly I don’t :( I tested with a spare 4010 and it blocks the lid from closing
If you’re not worried about aesthetics, you could cut a hole in the case or just leave it off.
Even if you put a blower fan, you’d need to drill holes so that could actually pull air from the side, like with the other one. Blocking its intake means it’ll do nothing but generate its own heat.
Edit: also, while these cards are pretty tolerant of heat so as not to die, they will definitely misbehave and cause data errors while above normal operating temps.
Maybe add a hole to your cpu fan duct so it blows across that heatsink too?
Interesting idea, might be worth expanding the thought and 3D printing a guide duct to redirect some of the airflow to the SAS card